Double-layer large-capacity light shaker instrument introduction: This series of equipment can be widely used in plant cultivation, seed germination, seedlings, tissue cells, microbial culture; insect, small animal breeding and other uses of constant temperature, constant temperature test. Double-layer large-capacity light shaker instrument features: ★ inclined humane control panel, large screen backlit LCD display, more good visual effects. ★ Run parameter memory function, to avoid tedious operations and password lock, to eliminate human error. ★ There is an incoming call recovery function, which is not affected by the power interruption. The device can automatically resume operation according to the original setting procedure. ★ With a strong and fast cooling system, the cooling requirement is realized instantly and with automatic frost function ★ The most advanced large torque motor guarantees continuous work without maintenance and maintenance-free. ★ No need to enter the cooling coefficient, automatic temperature adjustment, avoiding the tedious thermostat settings (distinguishable from other brands) ★ The heating rate can be increased or decreased according to the specific requirements of the experiment. ★ The use of microcomputer intelligent control system, powerful, anti-interference ability. It can realize the free combination of temperature and illuminance parameters of day and night 1-24 time periods, up to ten segments programming. ★ Quiet design, electrostatic spray box, with tempered glass viewing window, at any time to observe the light conditions in the box. ★ built-in top light, special biological light source, good spectral characteristics, high intensity, low heat, especially suitable for experimental requirements. ★ Over-temperature sound and light alarm automatic protection function, to avoid damage to the test sample due to overheating or overcooling. ★The shell is made of high-quality steel plate, full-mirror stainless steel cavity components, never rust. TS-2102GZ: Temperature range: 4∽60°C (without light) TS-2112GZ: The parameters of large-capacity light shaker arranged by you Oleic Acid,Oleic Fatty Acid,Pesticide Emulsifier,Tallowamine Pesticide Emulsifer Sichuan Tianyu Oleochemical Co., Ltd , https://www.sclthoil.com
Speed ​​range: 30∽300 rpm
Standard configuration: 250ml × 35 branches 500ml × 24 branches
Maximum capacity: 250ml×70 support or 500ml×48 support or 1000ml×24 support
Light intensity: divided into six levels of light 1.2.3.4.5.6 up to 12000LX
Temperature range: 4∽60°C (without light)
Speed ​​range: 30∽300 rpm Standard configuration: 250ml×45 branch 500ml×36 branch Maximum capacity: 250ml×90 branches or 500ml×72 branches or 1000ml×36 branches Light intensity: divided into six levels of illumination 1.2.3.4.5.6 Up to 15000 LX