Vertical Single Row Fans Air Cooled Condenser

  • Model NO.: SHSL-D2-602-14X630F7
  • Refrigerant: CHF2Cl
  • Material: Copper
  • Heat Transfer Mode: Recuperative
  • Application Field: Automotive Industry
  • Condition: New
  • Inlet/Outlet Pipe Diameter: Dn125
  • Air Pressure: 79kpa
  • Fan Motor Power: 790
  • Trademark: Shenglin
  • Specification: ISO9001: 2000
  • HS Code: 8415909000
  • Condensation Forms: Air-Cooled
  • Type: Air Cooled Condenser
  • Structural Form: Horizontal
  • Form: Fixed Tube-Sheet
  • Certification: RoHS, ISO, UL, CE
  • Product Name: Vertical Single Row Fans Air Cooled Conde
  • Heat Transfer: 395kw
  • Feature: Equipped with Water Circulating Pumps
  • Cooling Method: Air Cooled
  • Transport Package: Wooden Packing
  • Origin: Shanghai, China
            Vertical Single row fans air cooled condenser

Remote condensers
Heat Exchange Finned Coils
All finned coils of remote condensers are produced with copper pipes and aluminium
fins with high efficiency pyramidal corrugation
The frame of finned coils is produced in galvanized steel with thickness suitable to weight
of heat exchanger.
All pipes are expanded on aluminium counter-endplates to avoid any contact between
copper pipes and steel frame and therefore any possible pipe damage.
Endplate holes corresponding to header nipples are larger to avoid that vibrations and
dilatations can damage pipes.
 
External Frame Carenatura
Condensers are produced with galvanized steel frame, epoxy painted RAL9016.
Fan cowls are high type to get max. performances and min. Noise.
 
Fan Motors
All Standard fans are 400V - 3F - 50Hz
On request: fans 60 Hz available for all diameters
Fans have external rotor, protection IP54, very high efficiency.
Motors and fans are statically and dynamically balanced.
 
Declared Capacities
Declared capacities are calculated and tested in our test lab according to ENV327.
Ambient temperature +25°C
Condensation temperature +40°C
Refrigerant R404a
 
Test
All coils are tested with dry air and are properly degreased.
Standard design pressure is 30 bar. The version with max. design pressure 45 bar is
available for all models
 
Quick Selection
Condensers can be selected if you know type of compressor, cooling capacity and working
conditions according to following scheme and parameters

 Technical parameter
Dry cooler D4 series parameter(fin space 2.1mm)
Type D4-176-4X800 D4-191-4X800 D4-205-4X800 D4-267-6X800 D4-291-6X800
Capacity Water 35ºC outdoor temp. Inlet 45ºC, KW 175.6 190.6 205.4 266.5 291.2
outlet 40ºC
20% Glycol Inlet   45ºC 171.5 186.5 201.0 258.0 282.3
outlet 40ºC
Medium Water flow M3/h 30.5 33.1 35.7 46.3 50.6
Pressure drop kPa 98 84 70 48 39
Air flow M3/h 86771 83195 79955 13054 124786
Fan motor(400V/3N/50HZ) W 7200 7200 7200 10800 10800
A 15.2 15.2 15.2 22.8 22.8
Fan No X φ 2X2X800 2X2X800 2X2X800 2X3X800 2X3X800
Sound pressure level dB(A) 54.0 54.0 54.0 56.0 56.0
10m
Dimension L mm 2670 2670 2670 3870 3870
W mm 2250 2250 2250 2250 2250
H mm 2000 2000 2000 2000 2000
Inlet φ mm 2X2-1/2" 2X2-1/2" 2X2-1/2" 2X3" 2X3"
Inlet φ mm 2X2-1/2" 2X2-1/2" 2X2-1/2" 2X3" 2X3"
Product weight(empty) kg 698 735 835 1135 1225
 
Type D4-428-10X800 D4-488-10X800
Capacity Water 35ºC outdoor temp. Inlet 45ºC, KW 427.6 488.1
outlet 40ºC
20% Glycol Inlet   45ºC 411.0 476.6
outlet 40ºC
Medium Water flow M3/h 74.3 84.9
Pressure drop kPa 28 60
Air flow M3/h 216938 202183
Fan motor(400V/3N/50HZ) W 18000 18000
A 38.00 38.00
Fan No X φ 2X5X800 2X5X800
Sound pressure level dB(A) 60.0 60.0
10m
Dimension L mm 6270 6270
W mm 2520 2520
H mm 2000 2000
Inlet φ mm 2X4" 2XDN125
Inlet φ mm 2X4" 2XDN125
Product weight(empty) kg 2159 2250
 
 
Applications:

1, textile, machinery, ceramics, fine chemicals, metallurgy, glass, metal, leather and other manufacturing industries;
2, electroplating, electronics, footwear, printing, plastics, clothing, printing, packaging, food processing industry;
3, hospitals, waiting rooms, schools, waiting rooms, supermarkets, laundry room;
Cooler instance, click to enlarge
1, kitchen, vegetable market, a large entertainment center, underground parking, railway stations and other public places;  greenhouse, flowers, poultry, livestock and other types of farms;
2, the existing air conditioning and blower equipment modification and installation.
3, the requirements of high humidity places (such as textiles, planting, etc.), can be part of the interior installation design.
4, the requirements of low humidity, low humidity and high cleanliness of the place, please carefully consider the suitability of use.



Vertical Single Row Fans Air Cooled Condenser
Vertical Single Row Fans Air Cooled CondenserVertical Single Row Fans Air Cooled CondenserVertical Single Row Fans Air Cooled CondenserVertical Single Row Fans Air Cooled Condenser
Vertical Single Row Fans Air Cooled Condenser

Batch Type Oil Distillation Plant

The Waste Engine Oil Distillation Plant is used to refine waste engine oil, crude oil and fuel oil after pyrolysis process into diesel grade oil, gasoline or and base oil. The daily capacity of this plant is about 5-6 tons.

 Waste Engine Oil Distillation Plant

Flow-chat of waste engine oi Distillation Plant

Waste Engine Oil Distillation Plant

Advantage of waste engine oi distillation plant

1. Unique and original manufacturing and technology with our own formula of our equipments in China;

2. Unique horizontal design, high oil output with about 90% oil yield and 100% conversion rate, highly effective and profitable;

3. Good quality end product oil as the substitution of standard diesel oil in usage;

Automatic submerged welding technology, ultrasonic nondestructive testing, both manual and the automatic safety devices;

4. Sync gas recycling system: fully burned after recycling and utilization, saving fuel and preventing pollution;

5. National patent, unique heat insulation shell: high efficiency temperature keeping, excellent energy-saving effect;

6. High condensing efficiency condensers with more oil output. Good quality oil, longer lifetime, and easy to clean;

7. National patent water film smoke scrubbers: efficient removal of the acid gas and dust of the smoke, environmental friendly to meet related national standards.

 

Technical Parameter of Waste engine Oil Distillation Plant

NO.

Item

Technical Parameter

1

Suitable Raw Materials

Waste engine oil, Pyrolysis fuel oil, crude oil

2

Structure

Horizontal Type

3

Capacity(24 hours)

3.5-6.5Mt

4

Work Pressure

Normal Pressure

5

Oil Yield

80%-90%

6

Power

18 kw/H

7

Cooling Method

Cycle water

8

Condensers

4 pieces of Vertical condensers

9

Emission Treatment

New DE-sulfurization Smoke Scrubbers

10

Heating Method

Hot Air

11

Type of Installation

With Foundation

12

Noise dB(A)

≤85

13

Dimension of Reactor(mm)

Ф2200×6000

Ф2500×8800

14

Operating Mode

Semi-continuous Operation

15

Main Chamber Weight (MT)

10~13Mt

16

Total Weight(MT)

25~35Mt

17

Installation Space Required

35m*15m

18

End Product

Non-standard diesel oil

19

Manpower

1~2/shift

20

Shipment Requirement

2*40HC=Ф2200×6000

1*40HC+1*40FR=Ф2500×8800

 

Batch Type Oil Distillation Plant

Batch Type Oil Distillation Plant,Batch Distillation Column,Waste Oil To Diesel,Oil Distillation Plant

Shangqiu Jinpeng Industrial Co., Ltd. , https://www.recyclingthewaste.com