We have supplied our Lighting poles to Australia, Columbia, England, Kuwait, Iraq, Philippines, Pakistan and etc.
Our Lighting poles are made from quality sheet through bending,
forming, automatic welding and hot galvanization. We can reach one-run
machining length of 14m and can bend sheet of thickness up to 45mm. We
adopt advanced welding procedures, automatically weld main joints and
reach rank-II welding quality.
Lighting Pole, Transmission Line Pole, Solar Lighting Pole, Single Arm Lighting Pole Jiangsu Xinjinlei Steel Industry Co., Ltd. , https://www.steelpolejl.comchina directional hydraulic valves rexroth
Product Information
 - ISO 4401 and CETOP-RP 121 H
china directional hydraulic valves rexroth
Product Information
 - ISO 4401 and CETOP-RP 121 H
Hydraulic Solenoid Valve
Model NO.: 4WE6E61CG24N9Z5L
Pressure: High Pressure
Valve Structure: Direct-Acting Piston Structure
Power Supply: DC Solenoid Valve
Usage: Drain
Standard: DIN
Application: Industrial Usage
Size: Ng6
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: Ningbo
HS Code: 84812010
Model NO.: 4WE6E61CG24N9Z5L
Pressure: High Pressure
Valve Structure: Direct-Acting Piston Structure
Power Supply: DC Solenoid Valve
Usage: Drain
Standard: DIN
Application: Industrial Usage
Size: Ng6
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: Ningbo
HS Code: 84812010
- Porting pattern to DIN 24 340 form A,
- Wet pin DC or AC solenoids with removable coil
- Solenoid coil can be rotated through 90¡ã
- It is not necessary to drain oil when the coil is replaced
- Fault override button, optional
- Waterproof pin plug, optionalÂ
- Large-scope suitable voltage, optional
Â
Type WE valves are solenoid operated directional spool valves. They control the start, stop and direction ofÂ
flow.
The directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and one orÂ
two return springs (4).
In the de-energised condition the control spool (3) is held in the neutral or initial position by means of returnÂ
springs (4) (except for impulse spools). The control spool (3) is actuated via wet pin solenoids (2).
To guarantee satisfactory operation care should be taken to ensure that the solenoid pressure chamber is filledÂ
with oil.
The control spool(3) is moved to the expected position by solenoid(2) and pushing rod(5). This gives free-flowÂ
from P to A and B to T or P to B and A to T.
When solenoid (2) is de-energised, the control spool (3) is returned to its initial position by means of the returnÂ
springs (4).Â
The solenoids may also control the control spool (3) by an optional override button(6) Â under the de-energisedÂ
condition.
Type 4WE 6.. L6X/O...(only possible for symbols A, C and D)
This version has 2 switched positions and 2 solenoids without detent. Â
Type 4WE 6.. L6X/OF... (impulse spool, only for symbols A, C and D)
This version has 2 switched positions, 2 solenoids and a detent. Both switched positions are thus fixedÂ
alternately and so it is unnecessary to continually energise the solenoid.
Cartridge throttle (type 4WE 6..L6X/¡-/B.. )
The cartridge throttle is necessary since actual flow may be larger than theÂ
performance limits of the valve during switching process.
This is inserted in the P channel of the directional control valve.
For application in voltage pulsation, solenoids with large scope voltage
are recommended.
For application in high protective grade, waterproof plug should be used.
- Porting pattern to DIN 24 340 form A,
- Wet pin DC or AC solenoids with removable coil
- Solenoid coil can be rotated through 90¡ã
- It is not necessary to drain oil when the coil is replaced
- Fault override button, optional
- Waterproof pin plug, optionalÂ
- Large-scope suitable voltage, optional
Â
Type WE valves are solenoid operated directional spool valves. They control the start, stop and direction ofÂ
flow.
The directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and one orÂ
two return springs (4).
In the de-energised condition the control spool (3) is held in the neutral or initial position by means of returnÂ
springs (4) (except for impulse spools). The control spool (3) is actuated via wet pin solenoids (2).
To guarantee satisfactory operation care should be taken to ensure that the solenoid pressure chamber is filledÂ
with oil.
The control spool(3) is moved to the expected position by solenoid(2) and pushing rod(5). This gives free-flowÂ
from P to A and B to T or P to B and A to T.
When solenoid (2) is de-energised, the control spool (3) is returned to its initial position by means of the returnÂ
springs (4).Â
The solenoids may also control the control spool (3) by an optional override button(6) Â under the de-energisedÂ
condition.
Type 4WE 6.. L6X/O...(only possible for symbols A, C and D)
This version has 2 switched positions and 2 solenoids without detent. Â
Type 4WE 6.. L6X/OF... (impulse spool, only for symbols A, C and D)
This version has 2 switched positions, 2 solenoids and a detent. Both switched positions are thus fixedÂ
alternately and so it is unnecessary to continually energise the solenoid.
Cartridge throttle (type 4WE 6..L6X/¡-/B.. )
The cartridge throttle is necessary since actual flow may be larger than theÂ
performance limits of the valve during switching process.
This is inserted in the P channel of the directional control valve.
For application in voltage pulsation, solenoids with large scope voltage
are recommended.
For application in high protective grade, waterproof plug should be used.